SOLOIST CONTROL
INTERFACE
PRELIMINARY SPECIFICATIONS
Version 7.5
March 10,1997
ADTEC
PRODUCTIONS,
INC.
2231-1 Corporate Square Blvd. Jacksonville, FL 32216 1-904-720-2003
Page view 0
1 2 3 4 5 6 ... 20 21

Summary of Contents

Page 1 - PRODUCTIONS

SOLOIST CONTROLINTERFACEPRELIMINARY SPECIFICATIONSVersion 7.5March 10,1997ADTECPRODUCTIONS,INC.2231-1 Corporate Square Blvd. Jacksonville, FL 32216

Page 2 - NOTICE TO USER

10Description- Displays or changes whether or not spots are to be shuffled in the current playlist. If shuffle is ON, anyrollover or rollunder or addi

Page 3 - CONTROL INTERFACE

11Terse Example- Command- <NAME> BL 1Response- 0Errors- (Terse, Verbose) 2, ERROR- Bad ArgumentsVIDEODescription- Displays or changes the curre

Page 4 - CONTROL PROTOCOL

12ERASE (clears the volatile as well as the non-volatile lists)LOAD (copies a list from non-volatile to volatile memory)PTR [number] (display or chan

Page 5

13NOTE: Only multiple commands can be entered with the PIPE character, multiple schedule events can NOT be addedon a single line with the pipe charact

Page 6 - COMMANDS

14Errors- (Terse, Verbose) 2, ERROR- Bad Arguments6, ERROR- Load failed- EEPROM missing or bad7, ERROR- Save failed- EEPROM missing or bad8, ERROR- Er

Page 7

15Verbose Example- Command- <NAME> COM2Response- OK38400 Baud, 8 Data Bits, 1 Stop Bit(s), NO parityVerbose Example- Command- <NAME> COM2

Page 8 - TRANSPORT

16Blank= BLACKErrorLimit= 3Attenuation= 0Com1= Baud-38400, Data Bits-8, Stop Bits-1, Parity- NONECom2= Baud-38400, Data Bits-8, Stop Bits-1, Parity- N

Page 9 - TIMECODE

17Response- 000 00 000 NESTLE 0011286 00 00 30 04 030 10 22 96 04 5800 00 001 HAINES 0011319 00 00 30 01 030 08 08 96 06 23Terse Example- Command- <

Page 10

18Terse Example- Command- <NAME> BAResponse- 007 05 03 10 97MANUFACTUREDescription- Displays the manufacturing information. ( ProductName, PartN

Page 11 - ERRORLIMIT

19Total Memory= 4194304 bytesApplication Code & Data= 120030 bytesDirectory Buffer= 8000 bytesFAT Buffer= 131072 bytesVideo Buffer= 3899392 bytesS

Page 12 - SCHEDULE

2NOTICE TO USERAll information contained in this document is the intellectual property ofAdtec Productions, Inc., and all rights to this property are

Page 13

20Verbose Example- Command- <NAME> MODEM ATE0V0X0S0=2Response- OKTerse Example- Command- <NAME> MOResponse- 0ATETerse Example- Command- &l

Page 14

21Required Arguments- NoneOptional Arguments- NoneVerbose Example- Command- <NAME> RESETResponse- OKTerse Example- Command- <NAME> RSRespo

Page 15 - CONFIGURATION

3OVERVIEWThe Soloist Professional MPEG Player is a standalone digital video playercapable of playing MPEG1 video from a variety of disc mediums, inclu

Page 16 - DIRECTORY

4Full Duplex loop through RS-232 serial control-Allows for control using a single standard RS-232 serial port at baud rates up to 38400. Loop through

Page 17 - INVENTORY

5Depending on the command, the Soloist will respond with an appropriate ASCII message. These messages will beexplained under each command’s descriptio

Page 18 - MANUFACTURE

6This command would clear out the list, then add the spot named “NESTLE” tothe list, and finally begin playing, all with one command line.COMMANDSPLAY

Page 19

7Relevant Flags- Repeat, ShuffleRequired Arguments- NoneOptional Arguments- NoneVerbose Example- Command- <NAME> PREVIOUSResponse- OKTerse Examp

Page 20 - ATTENUATE

85, ERROR- Playlist has entries, no cueing allowedPLAYSPOTDescription- Play a specified spot. You must specify the spot name, or you may optionally sp

Page 21 - RESPONSE MESSAGES

9Required Arguments- FRAMEOptional Arguments- [+] (HR:MIN:SEC:FRAME), [-] (HR:MIN:SEC:FRAME)Verbose Example- Command- <NAME> INDEX + 00:00:02.00